Sunday, Nov. 22, 2026 A Vik Media Group publication
Mongevity Longevity in Motion
Leer en español

A new tonometer can change your dog’s intraocular pressure reading

☕ Includes a question for the family ↓

Intraocular pressurePart of a story we are following · 1 article · See every update
A couple walks along the Blue Mesa Trail among colorful badlands in Petrified Forest National Park.
A couple walks along the Blue Mesa Trail among colorful badlands in Petrified Forest National Park.Photo: NPS / Wikimedia Commons, Public domain

If your dog’s eye pressure number is different this year, the eye may be fine. The clinic may simply have a new device.

In a veterinary review published in November 2026, the authors explain that a change in a dog’s intraocular pressure reading can come from a new measuring instrument, not from a change inside the eye. The review looks at the tonometers used in dogs, and it matters most for dogs with glaucoma or dogs being watched for it.

How the study worked

This is an expert review, not a trial with a group of dogs. It pulls together what is known about how different tonometers behave and how vets should read the numbers over time, published in the J Small Anim Pract on November 13, 2026. Because it is a review, it offers guidance rather than new measurements from a set of dogs.

What is a tonometer, and why does it matter?

A tonometer is the instrument a vet uses to measure the pressure inside the eye. That pressure is a key piece of diagnosing and managing glaucoma in dogs.

The number you see is not a pure fact about the eye. It also depends on the device that produced it.

What they found

The review makes several plain points.

  • Newer devices have improved. Successive generations of veterinary tonometers are easier to carry and use, are more standardized, and agree better with direct pressure measurements.
  • Different devices are not interchangeable. Two tonometers can give different numbers for the same eye.
  • Other things move the number too. The cornea itself, the technique used, how your dog is feeling, and the setting of the exam all play a part.
  • Swapping or recalibrating a device can look like a real change. The reading may shift even though nothing changed in the eye.

For vets, the review says changing a tonometer should be treated as changing the whole measuring system, not just swapping a piece of equipment. The authors recommend that the clinic record the model and generation of the device. When a clinic switches, they suggest taking readings with both the old and new devices when possible, to set a fresh baseline for each dog.

The review also warns against two shortcuts. Average differences between devices should not be used as a simple correction for an individual dog. And a cutoff number for high eye pressure or suspected glaucoma should not be assumed to mean the same thing on every device.

So what do vets look at besides the number?

When pressure changes unexpectedly, the review says vets should consider two possibilities: a real change in the eye, or a change in how it was measured.

It also says the diagnosis and long-term monitoring of glaucoma should not rest on pressure alone. Vets should combine it with how well your dog can see and with the structure of the retina and the optic nerve. The goal, in the authors’ words, is to keep the clinical meaning of the pressure, not just a smooth line of numbers.

If your dog’s number jumps, that is a reason for a good conversation. It is not automatically a reason to worry.

What you can do today

At your dog’s next eye check, ask which tonometer was used, and write the model name next to the pressure number in your records. If the clinic has changed devices since the last visit, ask whether they took readings with both the old and new ones.

For clinicians and researchers

Design: Narrative review of tonometry in canine glaucoma, addressing how readings differ across successive veterinary tonometer generations and are affected by corneal properties, technique, patient state and clinical environment. No n, follow-up or comparator reported.

Main result: Measurements from different tonometers are not necessarily interchangeable. Replacing or recalibrating a device may produce an apparent intraocular pressure change that does not reflect biological change within the eye.

Main limitation: Review without original data or quantified inter-device differences in the abstract; recommendations rest on synthesis of existing literature rather than a prospective comparison.

Open question: Whether paired old-and-new device measurements can reliably establish a new individual baseline, and how thresholds for ocular hypertension and suspected glaucoma should be defined for each tonometer, remain to be tested.

Talk about it at home

Imagine you measure your height with a tape measure, and then a friend measures you with a different one that starts a little further along. You would get two different numbers, even though you did not grow. Eye pressure devices can be a bit like that, so scientists and vets try to keep track of which tool made which number.

Question for the table

What if two kids measured the same table with two different rulers and got different answers? How could you work out whether the table changed or the rulers were different?

Keep exploring

Copies this article and its questions so you can paste them into ChatGPT, Claude, Gemini or the AI you use, and keep the conversation going.

Got a question? Ask us ›

Get the best of longevity science by emailThe most useful new studies, in plain language and with the source. Free.

We'll email you once to confirm. Occasional messages from our sponsors, clearly labeled. Unsubscribe anytime. We never ask for health data.
Cite this article
AMA
Mongevity Desk. A new tonometer can change your dog’s intraocular pressure reading. Mongevity. Published November 21, 2026. Accessed November 22, 2026. https://mongevity.science/heart/2026/11/dog-intraocular-pressure-new-tonometer/
Vancouver
Mongevity Desk. A new tonometer can change your dog’s intraocular pressure reading [Internet]. Mongevity; 2026 Nov 21 cited 2026 Nov 22]. Available from: https://mongevity.science/heart/2026/11/dog-intraocular-pressure-new-tonometer/
APA
Mongevity Desk. (2026, November 21). A new tonometer can change your dog’s intraocular pressure reading. Mongevity. https://mongevity.science/heart/2026/11/dog-intraocular-pressure-new-tonometer/
For your website
<a href="https://mongevity.science/heart/2026/11/dog-intraocular-pressure-new-tonometer/">A new tonometer can change your dog’s intraocular pressure reading</a>

Free to share or quote with credit and a link.

Questions and answers

Does a different eye pressure number mean my dog's glaucoma is worse?
Not necessarily. The review says a new device, a recalibration, or a different exam setting can change the number without any real change in the eye. Your vet will weigh both possibilities.
What is a tonometer?
It is the instrument a vet uses to measure the pressure inside your dog's eye. That pressure is used in diagnosing and managing canine glaucoma.
Can my vet just adjust the new numbers to match the old ones?
The review advises against that. Average differences between devices should not be used as a simple correction for an individual dog. Taking readings with both old and new devices is the better way to set a new baseline.
Is eye pressure the only thing used to monitor glaucoma?
No. The review says pressure should be combined with how well your dog sees and with the structure of the retina and optic nerve.

Sources

  1. J Small Anim Pract: Changing tonometers, changing intraocular pressure? Rethinking intraocular pressure interpretation in dogs (PMID 43031315 · DOI 10.1111/jsap.70223) · 2026-11-22
Report an error